{"title":"Broad Bandpass Filters","description":"\u003cp\u003eTransmit a broad wavelength region when a wider signal band is useful. These designs offer different spectral windows, so compare both edges and any secondary transmission.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to choose:\u003c\/strong\u003e Use the full measured response to check useful signal and unwanted light across the detector range. Broad passbands should not be treated as narrow laser-line filters.\u003c\/p\u003e","products":[{"product_id":"bbp-560","title":"BBP-560 Broad Bandpass Filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eBBP-560 Reference Optical Response\u003c\/h2\u003e\n\u003cp\u003eBBP-560 is a broad bandpass filter. Its Bandpass Filters workbook curve matches factory reference BH-A38(BPF560).\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this interval is not established.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 93.420% at 554 nm. This is a sample measurement, not an order tolerance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelection note:\u003c\/strong\u003e The measured absolute 50% transmission edges are approximately 509.98 and 602.80 nm. The separately labelled UV-IR curve is a different reference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values describe a measured measured sample. Custom versions and production orders have their own agreed specifications.\u003c\/p\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cp\u003eCompare the full source spectrum and desired transmitted region. Tell us the working angle, dimensions and required rejection.\u003c\/p\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eDiscuss the wavelength response, substrate, dimensions and operating conditions with KUPO.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003cstrong\u003eCatalog cross-reference:\u003c\/strong\u003e BP560-D01; earlier reference BBP-560. Include either reference in your inquiry.\u003c\/p\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/BBP-560.html\" title=\"BBP-560 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about BBP-560\u003c\/h2\u003e\n\u003ch3\u003eWhat does the measured peak of BBP-560 represent?\u003c\/h3\u003e\n\u003cp\u003eThe measured peak is approximately 93.420% at 554 nm. That is the highest measured transmission point, not automatically a defined centre wavelength or a passband specification. Use the surrounding curve to judge the signal range.\u003c\/p\u003e\n\u003ch3\u003eDoes the 560 designation mean this is a narrow 560 nm bandpass?\u003c\/h3\u003e\n\u003cp\u003eDo not assume a narrow passband from the name. The customer sample-book curve matches the factory BH-A38(BPF560) reference, so this listing follows that measured response. If you need to isolate a narrow 560 nm signal, compare the complete curve and specify the bandwidth and blocking you need.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516669899007,"sku":"BBP-560","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/bbp-560-spectrum.jpg?v=1778712921"},{"product_id":"bbp-650","title":"BBP-650 650 nm bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e650 nm nominal-channel bandpass filter (BBP-650)\u003c\/h2\u003e\n\u003cp\u003eBBP-650 is a bandpass filter. The main high-transmission region is approximately 618-688 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-800 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 611-693.8 nm, giving a full width at half maximum (FWHM) of approximately 82.8 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 618-688 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-359 nm; 404-596 nm; 710-800 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.7% at 644 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e660 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 660 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003cstrong\u003eCatalog cross-reference:\u003c\/strong\u003e BP650-D01; earlier reference BBP-650. Include either reference in your inquiry.\u003c\/p\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/BBP-650.html\" title=\"BBP-650 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about BBP-650\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing BBP-650?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 618-688 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhich low-transmission regions are shown for BBP-650?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 300-359 nm; 404-596 nm; 710-800 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Red","offer_id":48516670259455,"sku":"BBP-650","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/bbp-650-spectrum.jpg?v=1778712927"},{"product_id":"bbp-626","title":"BBP-626 626 nm bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e626 nm nominal-channel bandpass filter (BBP-626)\u003c\/h2\u003e\n\u003cp\u003eBBP-626 is a bandpass filter. The main high-transmission region is approximately 548-705 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 539.2-712.7 nm, giving a full width at half maximum (FWHM) of approximately 173.5 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 548-705 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-519 nm; 738-1184 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 96.8% at 652 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 539.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 712.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e660 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 660 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003cstrong\u003eCatalog cross-reference:\u003c\/strong\u003e BP626-D01; earlier reference BBP-626. Include either reference in your inquiry.\u003c\/p\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/BBP-626.html\" title=\"BBP-626 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about BBP-626\u003c\/h2\u003e\n\u003ch3\u003eWhere does BBP-626 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 548-705 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eHow much rejection can I infer from the BBP-626 measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 300-519 nm; 738-1184 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Red","offer_id":48516670849279,"sku":"BBP-626","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/bbp-626-spectrum.jpg?v=1778712938"},{"product_id":"bh-a03","title":"BH-A03 Bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eBandpass filter (BH-A03)\u003c\/h2\u003e\n\u003cp\u003eBH-A03 is a bandpass filter. The main high-transmission region is approximately 603-671 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 597.8-677.6 nm, giving a full width at half maximum (FWHM) of approximately 79.8 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 603-671 nm; 1160-1188 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-363 nm; 392-587 nm; 693-935 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 92.8% at 616 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e660 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 660 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 1147-1200 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/BH-A03.html\" title=\"BH-A03 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about BH-A03\u003c\/h2\u003e\n\u003ch3\u003eWhere does BH-A03 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 603-671 nm; 1160-1188 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould BH-A03 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor BH-A03, additional regions reach at least 50% transmission at approximately 1147-1200 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516671176959,"sku":"BH-A03","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/bh-a03-spectrum.jpg?v=1778712947"},{"product_id":"bh-b19","title":"BH-B19 510-570 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e510-570 nm nominal pass-region bandpass filter (BH-B19)\u003c\/h2\u003e\n\u003cp\u003eBH-B19 is a bandpass filter. The main high-transmission region is approximately 512-561 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 507.6-566.8 nm, giving a full width at half maximum (FWHM) of approximately 59.3 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 512-561 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 383-498 nm; 584-779 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.7% at 543 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 507.9 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 566.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/BH-B19.html\" title=\"BH-B19 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about BH-B19\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for BH-B19?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 512-561 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCan I use the low points on the BH-B19 curve as a blocking guarantee?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 383-498 nm; 584-779 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516672291071,"sku":"BH-B19","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/bh-b19-spectrum.jpg?v=1778712968"},{"product_id":"g9017","title":"G9017 491-561 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e491-561 nm nominal pass-region bandpass filter (G9017)\u003c\/h2\u003e\n\u003cp\u003eG9017 is a bandpass filter. The main high-transmission region is approximately 496-558 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 492-562.6 nm, giving a full width at half maximum (FWHM) of approximately 70.6 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 496-558 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-483 nm; 576-779 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.9% at 543 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 492.2 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 562.3 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G9017.html\" title=\"G9017 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G9017\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing G9017?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 496-558 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhich low-transmission regions are shown for G9017?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 380-483 nm; 576-779 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516672717055,"sku":"G9017","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g9017-spectrum.jpg?v=1778712971"},{"product_id":"g8916","title":"G8916 480-590 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e480-590 nm nominal pass-region bandpass filter (G8916)\u003c\/h2\u003e\n\u003cp\u003eG8916 is a bandpass filter. The main high-transmission region is approximately 485-586 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 479.2-590.5 nm, giving a full width at half maximum (FWHM) of approximately 111.3 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 485-586 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-471 nm; 605-780 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95.3% at 519 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 479.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 590.2 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G8916.html\" title=\"G8916 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G8916\u003c\/h2\u003e\n\u003ch3\u003eWhere does G8916 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 485-586 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eHow much rejection can I infer from the G8916 measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 380-471 nm; 605-780 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516672946431,"sku":"G8916","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g8916-spectrum.jpg?v=1778712972"},{"product_id":"g74015","title":"G74015 527-581 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e527-581 nm nominal pass-region bandpass filter (G74015)\u003c\/h2\u003e\n\u003cp\u003eG74015 is a bandpass filter. The main high-transmission region is approximately 531-575 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 526.2-581.1 nm, giving a full width at half maximum (FWHM) of approximately 54.9 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 531-575 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 395-516 nm; 597-780 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.1% at 566 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 526.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 580.7 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G74015.html\" title=\"G74015 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G74015\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for G74015?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 531-575 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCan I use the low points on the G74015 curve as a blocking guarantee?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 395-516 nm; 597-780 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516672979199,"sku":"G74015","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g74015-spectrum.jpg?v=1778712973"},{"product_id":"g73814","title":"G73814 520-584 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e520-584 nm nominal pass-region bandpass filter (G73814)\u003c\/h2\u003e\n\u003cp\u003eG73814 is a bandpass filter. The main high-transmission region is approximately 523-575 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 517.5-581.1 nm, giving a full width at half maximum (FWHM) of approximately 63.6 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 523-575 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 383-388 nm; 393-506 nm; 598-780 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.4% at 553 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 517.8 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 580.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73814.html\" title=\"G73814 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73814\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing G73814?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 523-575 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhich low-transmission regions are shown for G73814?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 383-388 nm; 393-506 nm; 598-780 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516673011967,"sku":"G73814","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73814-spectrum.jpg?v=1778712974"},{"product_id":"g73813","title":"G73813 520-573 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e520-573 nm nominal pass-region bandpass filter (G73813)\u003c\/h2\u003e\n\u003cp\u003eG73813 is a bandpass filter. The main high-transmission region is approximately 524-567 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 519.5-573.2 nm, giving a full width at half maximum (FWHM) of approximately 53.7 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 524-567 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 382-384 nm; 390-509 nm; 588-774 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 93.4% at 560 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 519.9 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 572.7 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73813.html\" title=\"G73813 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73813\u003c\/h2\u003e\n\u003ch3\u003eWhere does G73813 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 524-567 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eHow much rejection can I infer from the G73813 measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 382-384 nm; 390-509 nm; 588-774 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516673208575,"sku":"G73813","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73813-spectrum.jpg?v=1778712975"},{"product_id":"g2812","title":"G2812 512-565 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e512-565 nm nominal pass-region bandpass filter (G2812)\u003c\/h2\u003e\n\u003cp\u003eG2812 is a bandpass filter. The main high-transmission region is approximately 513-559 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 509.9-564.4 nm, giving a full width at half maximum (FWHM) of approximately 54.5 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 513-559 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 386-501 nm; 581-780 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.9% at 543 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 510.1 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 564.1 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G2812.html\" title=\"G2812 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G2812\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for G2812?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 513-559 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCan I use the low points on the G2812 curve as a blocking guarantee?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 386-501 nm; 581-780 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516673241343,"sku":"G2812","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g2812-spectrum.jpg?v=1778712976"},{"product_id":"g73611","title":"G73611 510-545 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e510-545 nm nominal pass-region bandpass filter (G73611)\u003c\/h2\u003e\n\u003cp\u003eG73611 is a bandpass filter. The main high-transmission region is approximately 516-541 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 512.2-547 nm, giving a full width at half maximum (FWHM) of approximately 34.7 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 516-541 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 399-503 nm; 562-763 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.4% at 534 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 512.5 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 546.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73611.html\" title=\"G73611 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73611\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for G73611?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 516-541 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCan I use the low points on the G73611 curve as a blocking guarantee?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 399-503 nm; 562-763 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516673274111,"sku":"G73611","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73611-spectrum.jpg?v=1778712976"},{"product_id":"g2810","title":"G2810 508-563 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e508-563 nm nominal pass-region bandpass filter (G2810)\u003c\/h2\u003e\n\u003cp\u003eG2810 is a bandpass filter. The main high-transmission region is approximately 513-557 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 507.6-562.8 nm, giving a full width at half maximum (FWHM) of approximately 55.2 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 513-557 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-382 nm; 387-496 nm; 579-770 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.2% at 544 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 508.0 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 562.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G2810.html\" title=\"G2810 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G2810\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing G2810?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 513-557 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhich low-transmission regions are shown for G2810?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 380-382 nm; 387-496 nm; 579-770 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516673470719,"sku":"G2810","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g2810-spectrum.jpg?v=1778712977"},{"product_id":"g13909","title":"G13909 508-558 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e508-558 nm nominal pass-region bandpass filter (G13909)\u003c\/h2\u003e\n\u003cp\u003eG13909 is a bandpass filter. The main high-transmission region is approximately 510-552 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 505.9-556.3 nm, giving a full width at half maximum (FWHM) of approximately 50.4 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 510-552 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 386-497 nm; 570-769 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95% at 537 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 506.1 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 555.9 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G13909.html\" title=\"G13909 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G13909\u003c\/h2\u003e\n\u003ch3\u003eWhere does G13909 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 510-552 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eHow much rejection can I infer from the G13909 measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 386-497 nm; 570-769 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516673503487,"sku":"G13909","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g13909-spectrum.jpg?v=1778712978"},{"product_id":"g32701","title":"G32701 467-554 nm nominal pass-region bandpass filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/broad-bandpass-filters\"\u003eBroad Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003e467-554 nm nominal pass-region bandpass filter (G32701)\u003c\/h2\u003e\n\u003cp\u003eG32701 is a bandpass filter. The main high-transmission region is approximately 469-548 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 465.4-552.5 nm, giving a full width at half maximum (FWHM) of approximately 87.2 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 469-548 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-457 nm; 565-753 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.9% at 528 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 465.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 552.2 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 776-780 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G32701.html\" title=\"G32701 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G32701\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for G32701?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 469-548 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through G32701?\u003c\/h3\u003e\n\u003cp\u003eFor G32701, additional regions reach at least 50% transmission at approximately 776-780 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Broad Bandpass Filter \/ Green","offer_id":48516674158847,"sku":"G32701","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g32701-spectrum.jpg?v=1778712985"}],"url":"https:\/\/kupooptics.com\/collections\/broad-bandpass-filters.oembed","provider":"KUPO Optics","version":"1.0","type":"link"}