{"title":"Multi-Bandpass Filters","description":"\u003cp\u003eTransmit two or more separated wavelength regions through one optic. Compare every transmitted region with your light sources and detector response.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow to choose:\u003c\/strong\u003e All transmitted bands share the same optical path. Check unwanted secondary bands; a narrow band within a multiband design is not a standalone narrowband filter.\u003c\/p\u003e","products":[{"product_id":"mbp-a49","title":"MBP-A49 Dual-window short-wave infrared filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eDual-window short-wave infrared filter (MBP-A49)\u003c\/h2\u003e\n\u003cp\u003eMBP-A49 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 990-1140 nm; 1333-1579 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1800 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 1324.1-1590 nm, giving a full width at half maximum (FWHM) of approximately 265.9 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 990-1140 nm; 1333-1579 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-960 nm; 1170-1297 nm; 1625-1800 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 99.6% at 1475 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 800-965 nm:\u003c\/strong\u003e 0.703%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 1185-1305 nm:\u003c\/strong\u003e 1.504%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 1645-1800 nm:\u003c\/strong\u003e 0.384%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 1010-1135 nm:\u003c\/strong\u003e 98.373%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 1370-1570 nm:\u003c\/strong\u003e 98.983%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-wave infrared material inspection:\u003c\/strong\u003e Consider the two transmitted regions for a source and infrared detector used in material-contrast experiments. Match the illumination and detector response to the confirmed band limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-wavelength sensing:\u003c\/strong\u003e Evaluate sharing one optic between signals in the two short-wave infrared regions. Use source modulation or separate detection paths if independent channel readings are required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectroscopy-window selection:\u003c\/strong\u003e Compare the transmitted windows with the actual feature and reference wavelengths required by the measurement. Confirm the intervening rejection before finalizing the optical design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 983-1147 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/MBP-A49.html\" title=\"MBP-A49 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about MBP-A49\u003c\/h2\u003e\n\u003ch3\u003eWhere does MBP-A49 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 990-1140 nm; 1333-1579 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould MBP-A49 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor MBP-A49, additional regions reach at least 50% transmission at approximately 983-1147 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516667474175,"sku":"MBP-A49","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/mbp-a49-spectrum.jpg?v=1778712865"},{"product_id":"mbp-a60","title":"MBP-A60 Red and near-infrared dual-window filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eRed and near-infrared dual-window filter (MBP-A60)\u003c\/h2\u003e\n\u003cp\u003eMBP-A60 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 610-701 nm; 829-914 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 605.1-706.6 nm, giving a full width at half maximum (FWHM) of approximately 101.5 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 610-701 nm; 829-914 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-371 nm; 375-596 nm; 720-809 nm; 947-1200 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95.6% at 682 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 630-690 nm:\u003c\/strong\u003e 93.558%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 850-910 nm:\u003c\/strong\u003e 94.282%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRed and near-infrared illuminated inspection:\u003c\/strong\u003e Consider a common optical path for red and near-infrared illumination. Match each source band to the confirmed spectrum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVegetation-reflectance experiments:\u003c\/strong\u003e Evaluate red and near-infrared reflectance measurements with independently distinguishable channels. The filter alone does not separate simultaneous signals for an index calculation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-source optical sensing:\u003c\/strong\u003e Consider alternating red and near-infrared sources through one transmission optic. Confirm source bandwidth, detector response and channel separation for your measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 824-923 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/MBP-A60.html\" title=\"MBP-A60 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about MBP-A60\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for MBP-A60?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 610-701 nm; 829-914 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through MBP-A60?\u003c\/h3\u003e\n\u003cp\u003eFor MBP-A60, additional regions reach at least 50% transmission at approximately 824-923 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516667506943,"sku":"MBP-A60","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/mbp-a60-spectrum.jpg?v=1778712866"},{"product_id":"mbp-a50","title":"MBP-A50 Ultraviolet, visible and near-infrared multiband filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eUltraviolet, visible and near-infrared multiband filter (MBP-A50)\u003c\/h2\u003e\n\u003cp\u003eMBP-A50 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 401-634 nm; 841-1200 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 401-634 nm; 841-1200 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-312 nm; 324-325 nm; 366-386 nm; 674-799 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95.9% at 1160 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 410-610 nm:\u003c\/strong\u003e 93.842%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 700-780 nm:\u003c\/strong\u003e 0.962%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 870-1100 nm:\u003c\/strong\u003e 94.377%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-wavelength inspection:\u003c\/strong\u003e Consider retaining the measured visible and infrared regions in a common optical path. Match each illumination band and account for every transmitted region in the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared-path sensing:\u003c\/strong\u003e Use alternating light sources or separate detectors if you need to measure each wavelength band independently. Multiple passbands alone do not give separate readings for each band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIllumination-profile development:\u003c\/strong\u003e Compare the transmitted and attenuated regions with the source spectrum. Include the additional UV or longer-wavelength transmission visible in the reference spectrum when relevant to the setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 343-356 nm; 396-645 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/MBP-A50.html\" title=\"MBP-A50 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about MBP-A50\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing MBP-A50?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 401-634 nm; 841-1200 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhat should I check beyond the main transmission region of MBP-A50?\u003c\/h3\u003e\n\u003cp\u003eFor MBP-A50, additional regions reach at least 50% transmission at approximately 343-356 nm; 396-645 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 3-Band","offer_id":48516667572479,"sku":"MBP-A50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/mbp-a50-spectrum.jpg?v=1778712867"},{"product_id":"mbp-a48","title":"MBP-A48 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (MBP-A48)\u003c\/h2\u003e\n\u003cp\u003eMBP-A48 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 466-706 nm; 846-921 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 839.9-928.1 nm, giving a full width at half maximum (FWHM) of approximately 88.2 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 466-706 nm; 846-921 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-451 nm; 734-821 nm; 946-1200 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95.3% at 895 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 300-435 nm:\u003c\/strong\u003e 0.080%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 475-690 nm:\u003c\/strong\u003e 93.348%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 750-780 nm:\u003c\/strong\u003e 1.201%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 850-910 nm:\u003c\/strong\u003e 93.859%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 1000-1100 nm:\u003c\/strong\u003e 0.080%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-wavelength inspection:\u003c\/strong\u003e Consider retaining the measured visible and infrared regions in a common optical path. Match each illumination band and account for every transmitted region in the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared-path sensing:\u003c\/strong\u003e Use alternating light sources or separate detectors if you need to measure each wavelength band independently. Multiple passbands alone do not give separate readings for each band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIllumination-profile development:\u003c\/strong\u003e Compare the transmitted and attenuated regions with the source spectrum. Include the additional UV or longer-wavelength transmission visible in the reference spectrum when relevant to the setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 462-712 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/MBP-A48.html\" title=\"MBP-A48 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about MBP-A48\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for MBP-A48?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 466-706 nm; 846-921 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through MBP-A48?\u003c\/h3\u003e\n\u003cp\u003eFor MBP-A48, additional regions reach at least 50% transmission at approximately 462-712 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516667638015,"sku":"MBP-A48","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/mbp-a48-spectrum.jpg?v=1778712867"},{"product_id":"mbp-a35","title":"MBP-A35 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (MBP-A35)\u003c\/h2\u003e\n\u003cp\u003eMBP-A35 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 541-559 nm; 644-671 nm; 827-871 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 820.2-881.8 nm, giving a full width at half maximum (FWHM) of approximately 61.6 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 541-559 nm; 644-671 nm; 827-871 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 321-524 nm; 573-631 nm; 693-806 nm; 903-1082 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 96.5% at 845 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 350-520 nm:\u003c\/strong\u003e 0.191%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 540-560 nm:\u003c\/strong\u003e 86.079%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 580-630 nm:\u003c\/strong\u003e 1.132%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 650-670 nm:\u003c\/strong\u003e 89.591%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 690-810 nm:\u003c\/strong\u003e 1.081%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 830-870 nm:\u003c\/strong\u003e 90.897%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 890-1050 nm:\u003c\/strong\u003e 1.939%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-wavelength inspection:\u003c\/strong\u003e Consider retaining the measured visible and infrared regions in a common optical path. Match each illumination band and account for every transmitted region in the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared-path sensing:\u003c\/strong\u003e Use alternating light sources or separate detectors if you need to measure each wavelength band independently. Multiple passbands alone do not give separate readings for each band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIllumination-profile development:\u003c\/strong\u003e Compare the transmitted and attenuated regions with the source spectrum. Include the additional UV or longer-wavelength transmission visible in the reference spectrum when relevant to the setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 534-563 nm; 640-680 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/MBP-A35.html\" title=\"MBP-A35 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about MBP-A35\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing MBP-A35?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 541-559 nm; 644-671 nm; 827-871 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhat should I check beyond the main transmission region of MBP-A35?\u003c\/h3\u003e\n\u003cp\u003eFor MBP-A35, additional regions reach at least 50% transmission at approximately 534-563 nm; 640-680 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 3-Band","offer_id":48516667670783,"sku":"MBP-A35","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/mbp-a35-spectrum.jpg?v=1778712869"},{"product_id":"mbp-a34","title":"MBP-A34 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (MBP-A34)\u003c\/h2\u003e\n\u003cp\u003eMBP-A34 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 405-573 nm; 687-794 nm; 1070-1072 nm; 1196-1200 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 300-1200 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 397.4-579.4 nm, giving a full width at half maximum (FWHM) of approximately 182.1 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 405-573 nm; 687-794 nm; 1070-1072 nm; 1196-1200 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 300-361 nm; 597-657 nm; 830-1040 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95.2% at 514 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 415-560 nm:\u003c\/strong\u003e 93.079%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 610-650 nm:\u003c\/strong\u003e 1.718%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 695-785 nm:\u003c\/strong\u003e 92.976%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAverage measured transmission, 830-1000 nm:\u003c\/strong\u003e 0.528%. Calculated from the factory sample data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-wavelength inspection:\u003c\/strong\u003e Consider retaining the measured visible and infrared regions in a common optical path. Match each illumination band and account for every transmitted region in the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared-path sensing:\u003c\/strong\u003e Use alternating light sources or separate detectors if you need to measure each wavelength band independently. Multiple passbands alone do not give separate readings for each band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIllumination-profile development:\u003c\/strong\u003e Compare the transmitted and attenuated regions with the source spectrum. Include the additional UV or longer-wavelength transmission visible in the reference spectrum when relevant to the setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 384-387 nm; 680-803 nm; 1064-1079 nm; 1178-1200 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/MBP-A34.html\" title=\"MBP-A34 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about MBP-A34\u003c\/h2\u003e\n\u003ch3\u003eWhere does MBP-A34 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 405-573 nm; 687-794 nm; 1070-1072 nm; 1196-1200 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould MBP-A34 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor MBP-A34, additional regions reach at least 50% transmission at approximately 384-387 nm; 680-803 nm; 1064-1079 nm; 1178-1200 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 3-Band","offer_id":48516667703551,"sku":"MBP-A34","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/mbp-a34-spectrum.jpg?v=1778712870"},{"product_id":"g72918","title":"G72918 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G72918)\u003c\/h2\u003e\n\u003cp\u003eG72918 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 471-520 nm; 739-743 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 466.3-524.5 nm, giving a full width at half maximum (FWHM) of approximately 58.2 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 471-520 nm; 739-743 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-458 nm; 537-721 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.6% at 506 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 466.5 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 524.2 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 736-748 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G72918.html\" title=\"G72918 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G72918\u003c\/h2\u003e\n\u003ch3\u003eWhere does G72918 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 471-520 nm; 739-743 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould G72918 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor G72918, additional regions reach at least 50% transmission at approximately 736-748 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516672618751,"sku":"G72918","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g72918-spectrum.jpg?v=1778712970"},{"product_id":"g73608","title":"G73608 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G73608)\u003c\/h2\u003e\n\u003cp\u003eG73608 is a multi-region spectral filter. The main high-transmission region is approximately 507-530 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 503.7-537.2 nm, giving a full width at half maximum (FWHM) of approximately 33.5 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 507-530 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 394-496 nm; 553-726 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.4% at 522 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 504.0 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 536.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIlluminated inspection:\u003c\/strong\u003e Consider illumination within 507-530 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 747-753 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73608.html\" title=\"G73608 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73608\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing G73608?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 507-530 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhat should I check beyond the main transmission region of G73608?\u003c\/h3\u003e\n\u003cp\u003eFor G73608, additional regions reach at least 50% transmission at approximately 747-753 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516673536255,"sku":"G73608","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73608-spectrum.jpg?v=1778712979"},{"product_id":"g73607","title":"G73607 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G73607)\u003c\/h2\u003e\n\u003cp\u003eG73607 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 504-546 nm; 775-780 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 499.2-550.9 nm, giving a full width at half maximum (FWHM) of approximately 51.7 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 504-546 nm; 775-780 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 382-489 nm; 566-752 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94% at 528 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 499.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 550.5 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 771-780 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73607.html\" title=\"G73607 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73607\u003c\/h2\u003e\n\u003ch3\u003eWhere does G73607 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 504-546 nm; 775-780 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould G73607 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor G73607, additional regions reach at least 50% transmission at approximately 771-780 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516673732863,"sku":"G73607","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73607-spectrum.jpg?v=1778712980"},{"product_id":"g73606","title":"G73606 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G73606)\u003c\/h2\u003e\n\u003cp\u003eG73606 is a multi-region spectral filter. The main high-transmission region is approximately 500-523 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 495-528.3 nm, giving a full width at half maximum (FWHM) of approximately 33.2 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 500-523 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 382-485 nm; 540-738 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 92.2% at 506 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 495.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 527.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIlluminated inspection:\u003c\/strong\u003e Consider illumination within 500-523 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73606.html\" title=\"G73606 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73606\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for G73606?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 500-523 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCan I use the low points on the G73606 curve as a blocking guarantee?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or below 5% transmission are 382-485 nm; 540-738 nm. That threshold is a way to summarize this sample, not a guaranteed blocking specification. For a weak signal beside a bright unwanted wavelength, tell us the actual wavelengths and maximum leakage you can accept.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516673765631,"sku":"G73606","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73606-spectrum.jpg?v=1778712981"},{"product_id":"g13905","title":"G13905 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G13905)\u003c\/h2\u003e\n\u003cp\u003eG13905 is a multi-region spectral filter. The main high-transmission region is approximately 494-542 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 489.9-547.8 nm, giving a full width at half maximum (FWHM) of approximately 57.9 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 494-542 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-481 nm; 562-732 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.3% at 523 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 490.2 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 547.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e532 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 532 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 754-771 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G13905.html\" title=\"G13905 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G13905\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for G13905?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 494-542 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through G13905?\u003c\/h3\u003e\n\u003cp\u003eFor G13905, additional regions reach at least 50% transmission at approximately 754-771 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516673798399,"sku":"G13905","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g13905-spectrum.jpg?v=1778712982"},{"product_id":"g73504","title":"G73504 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G73504)\u003c\/h2\u003e\n\u003cp\u003eG73504 is a multi-region spectral filter. The main high-transmission region is approximately 486-517 nm. Use the full curve to match the desired signal and check secondary transmission before choosing the filter.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 481.6-522 nm, giving a full width at half maximum (FWHM) of approximately 40.4 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 486-517 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-474 nm; 534-708 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 93.9% at 510 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 481.8 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 521.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 729-744 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G73504.html\" title=\"G73504 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G73504\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing G73504?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 486-517 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhat should I check beyond the main transmission region of G73504?\u003c\/h3\u003e\n\u003cp\u003eFor G73504, additional regions reach at least 50% transmission at approximately 729-744 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516673831167,"sku":"G73504","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g73504-spectrum.jpg?v=1778712982"},{"product_id":"g32503","title":"G32503 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G32503)\u003c\/h2\u003e\n\u003cp\u003eG32503 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 490-507 nm; 762-772 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 481.7-515.6 nm, giving a full width at half maximum (FWHM) of approximately 33.9 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 490-507 nm; 762-772 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 557-712 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 93.9% at 498 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 482.4 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 514.8 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIlluminated inspection:\u003c\/strong\u003e Consider illumination within 490-507 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 750-780 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G32503.html\" title=\"G32503 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G32503\u003c\/h2\u003e\n\u003ch3\u003eWhich part of the spectrum is most useful when choosing G32503?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 490-507 nm; 762-772 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eWhat should I check beyond the main transmission region of G32503?\u003c\/h3\u003e\n\u003cp\u003eFor G32503, additional regions reach at least 50% transmission at approximately 750-780 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516674060543,"sku":"G32503","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g32503-spectrum.jpg?v=1778712984"},{"product_id":"g32502","title":"G32502 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (G32502)\u003c\/h2\u003e\n\u003cp\u003eG32502 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 481-516 nm; 736-738 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain band at half-peak transmission:\u003c\/strong\u003e Approximately 477.5-520.5 nm, giving a full width at half maximum (FWHM) of approximately 43.1 nm. This describes the main band only; other transmitted regions may remain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 481-516 nm; 736-738 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 380-471 nm; 532-707 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 93.1% at 502 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 477.7 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 520.1 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 729-749 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/G32502.html\" title=\"G32502 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about G32502\u003c\/h2\u003e\n\u003ch3\u003eWhere does G32502 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 481-516 nm; 736-738 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould G32502 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor G32502, additional regions reach at least 50% transmission at approximately 729-749 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516674126079,"sku":"G32502","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/g32502-spectrum.jpg?v=1778712984"},{"product_id":"b14110","title":"B14110 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (B14110)\u003c\/h2\u003e\n\u003cp\u003eB14110 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 381-523 nm; 758-767 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 381-523 nm; 758-767 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 550-729 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.6% at 494 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 530.5 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 753-777 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/B14110.html\" title=\"B14110 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about B14110\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for B14110?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 381-523 nm; 758-767 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through B14110?\u003c\/h3\u003e\n\u003cp\u003eFor B14110, additional regions reach at least 50% transmission at approximately 753-777 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516679074047,"sku":"B14110","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/b14110-spectrum.jpg?v=1778713034"},{"product_id":"b6809","title":"B6809 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (B6809)\u003c\/h2\u003e\n\u003cp\u003eB6809 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 380-512 nm; 752-761 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 380-512 nm; 752-761 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 541-724 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 94.9% at 469 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 519.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 747-769 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/B6809.html\" title=\"B6809 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about B6809\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for B6809?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 380-512 nm; 752-761 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through B6809?\u003c\/h3\u003e\n\u003cp\u003eFor B6809, additional regions reach at least 50% transmission at approximately 747-769 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516679270655,"sku":"B6809","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/b6809-spectrum.jpg?v=1778713035"},{"product_id":"b71408","title":"B71408 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (B71408)\u003c\/h2\u003e\n\u003cp\u003eB71408 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 380-504 nm; 740-748 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 380-504 nm; 740-748 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 527-714 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 95.2% at 480 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 509.8 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 736-757 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/B71408.html\" title=\"B71408 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about B71408\u003c\/h2\u003e\n\u003ch3\u003eWhat high-transmission regions should I compare for B71408?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 380-504 nm; 740-748 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould a broad-response detector see another band through B71408?\u003c\/h3\u003e\n\u003cp\u003eFor B71408, additional regions reach at least 50% transmission at approximately 736-757 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516679303423,"sku":"B71408","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/b71408-spectrum.jpg?v=1778713036"},{"product_id":"b8507","title":"B8507 Multi-region spectral filter","description":"\u003cnav aria-label=\"Product family\"\u003e\u003cp\u003e\u003ca href=\"\/collections\/all-products\"\u003eAll optics\u003c\/a\u003e \/ \u003ca href=\"\/collections\/multi-bandpass-filter\"\u003eMulti-Bandpass Filters\u003c\/a\u003e\u003c\/p\u003e\u003c\/nav\u003e\u003cstyle\u003e\n.ko-reviewed{color:#222;font-family:inherit;line-height:1.65;overflow-wrap:anywhere}\n.ko-reviewed *{box-sizing:border-box}.ko-reviewed h2,.ko-reviewed h3{color:#005F96;line-height:1.3}\n.ko-reviewed h2{font-size:24px;margin:0 0 1rem}.ko-reviewed h3{font-size:19px;margin:1.7rem 0 .65rem}\n.ko-reviewed p{margin:.6rem 0 1rem}.ko-reviewed ul{padding-left:1.25rem;margin:.6rem 0 1rem}\n.ko-reviewed li{padding-left:.15rem;margin:.55rem 0}.ko-reviewed .ko-note{border-left:3px solid #c9dae4;padding:.65rem 1rem;background:#f7fafc;font-size:.95em}\n.ko-reviewed a{color:#005F96;text-decoration:underline}\n\n@media(max-width:480px){.ko-reviewed h2{font-size:22px}.ko-reviewed h3{font-size:18px}.ko-reviewed .ko-note{padding:.65rem .8rem}}\n\u003c\/style\u003e\u003csection class=\"ko-reviewed\"\u003e\u003ch2 class=\"ko-catalog-description-title\"\u003eMulti-region spectral filter (B8507)\u003c\/h2\u003e\n\u003cp\u003eB8507 is a multi-region spectral filter. The reference spectrum shows multiple high-transmission regions at approximately 380-492 nm; 713-721 nm. Light from these bands passes through the same optic. Check every band against your light source and detector. To measure the bands separately, use alternating light sources or separate detection paths.\u003c\/p\u003e\n\u003ch3\u003eOptical performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured wavelength range:\u003c\/strong\u003e 380-780 nm. Performance outside this measured interval is not established by this curve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or above 80% transmission:\u003c\/strong\u003e 380-492 nm; 713-721 nm. Approximate measured intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelected regions at or below 5% transmission:\u003c\/strong\u003e 516-686 nm. Measured sample intervals; confirm the required blocking for your order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak transmission:\u003c\/strong\u003e Approximately 93.8% at 470 nm. Peak wavelength is not the same as a defined centre wavelength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasured edge at 50% transmission:\u003c\/strong\u003e Approximately 498.6 nm. Interpolated absolute-transmission crossing, checked against the factory summary. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomization:\u003c\/strong\u003e We can customize stock and sample-book designs. Tell us the wavelength response, size and operating conditions you need.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ko-note\"\u003eThese values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.\u003c\/p\u003e\n\u003ch3\u003eApplications to consider\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e488 nm illuminated inspection:\u003c\/strong\u003e Consider a source around 488 nm. Match the full source bandwidth to the curve, and check ambient-light rejection over the detector response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical sensing channels:\u003c\/strong\u003e Evaluate the transmitted region for a source-and-detector pair. Secondary transmitted light may require additional blocking or a detector with a limited response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluorescence instrument development:\u003c\/strong\u003e Consider the profile for an excitation or collection channel after matching both spectra. Confirm rejection of the excitation line and other transmitted bands in the complete optical layout.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing this filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional regions reach at least 50% transmission at approximately 708-730 nm. Include these in the detector and blocking assessment.\u003c\/li\u003e\n\u003cli\u003eCheck the full wavelength range of your light source, the wavelengths your detector responds to, and how much unwanted light you need to block. Use the full curve when choosing a filter; the product code and peak do not tell the whole story.\u003c\/li\u003e\n\u003cli\u003eTell us the angle at which light reaches the filter and whether the beam is parallel or converging. For demanding rejection or high-power use, confirm the required blocking and power-handling specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustom options\u003c\/h3\u003e\n\u003cp\u003eStart with this stock or sample-book design, then tell us what you need to change. We can discuss the wavelength bands, transmission, blocking, angle, glass material, size and operating conditions with you, and agree a specification for your custom filter.\u003c\/p\u003e\u003c\/section\u003e\u003ch3\u003eTransmission spectrum\u003c\/h3\u003e\u003ciframe src=\"https:\/\/charts.kupooptics.com\/B8507.html\" title=\"B8507 transmission spectrum with wavelength readout\" loading=\"lazy\" width=\"100%\" height=\"880\" style=\"border:0;width:100%;height:clamp(640px,calc(43vw + 320px),880px);\" referrerpolicy=\"no-referrer-when-downgrade\"\u003e\u003c\/iframe\u003e\u003csection class=\"ko-reviewed ko-product-faq\" aria-label=\"Product questions\"\u003e\u003ch2\u003eQuestions about B8507\u003c\/h2\u003e\n\u003ch3\u003eWhere does B8507 transmit at least 80% in the measured curve?\u003c\/h3\u003e\n\u003cp\u003eThe measured regions at or above 80% transmission are 380-492 nm; 713-721 nm. They are measured intervals, not guaranteed passband tolerances. Compare the full curve with the signal wavelengths you need to retain.\u003c\/p\u003e\n\u003ch3\u003eCould B8507 pass light outside its main band?\u003c\/h3\u003e\n\u003cp\u003eFor B8507, additional regions reach at least 50% transmission at approximately 708-730 nm. If your detector responds there, include that light in the background assessment or discuss an additional blocking requirement.\u003c\/p\u003e\u003c\/section\u003e\u003cp\u003e\u003ca href=\"\/pages\/contact\"\u003e\u003cstrong\u003eDiscuss this filter with KUPO\u003c\/strong\u003e\u003c\/a\u003e - include the product reference, source wavelength, working angle and required dimensions.\u003c\/p\u003e\u003cstyle\u003e#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:27px;font-weight:500;line-height:1.4;letter-spacing:-.01em;color:#0c324b;background:#f0f6f9;padding:20px 24px;}#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title+p{border-bottom:0;}@media(max-width:650px){#MainContent .ko-reviewed\u003eh2.ko-catalog-description-title{font-size:24px;}}\u003c\/style\u003e","brand":"KUPO Optics","offers":[{"title":"Multi-Bandpass Filter \/ 2-Band","offer_id":48516679434495,"sku":"B8507","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/8651\/1359\/files\/b8507-spectrum.jpg?v=1778713037"}],"url":"https:\/\/kupooptics.com\/collections\/multi-bandpass-filter.oembed","provider":"KUPO Optics","version":"1.0","type":"link"}