CTO-016 is a warming color-correction filter. It reduces blue-to-green light relative to longer visible wavelengths. This can give a suitable broadband light source a warmer balance. Average transmission in the sample is 25% over 400-500 nm, 47.1% over 500-600 nm, 88.6% over 600-700 nm. The resulting light output also depends on the lamp spectrum.

  • Product family: Color Temperature Orange (CTO)
  • Measured wavelength range: 380–800 nm
  • Published response: Transmittance

Values shown are sample measurements. Final specifications are agreed for your order.

Calculated color-temperature shift

5600 K → 2750 K (+185 mired)

Calculated from the measured transmission curve with a blackbody source at the starting temperature shown (CIE 1931 2°). The shift on your fixture depends on the lamp spectrum.

MEASURED OPTICAL RESPONSE

Read the light.

Original published sample data.

Download spectrum CSV ↓
Loading measured spectrum…

Nearest measured point shown, without interpolation. The chart is drawn on a 0–100% scale; the readout and CSV keep the recorded values, where small readings just below 0% or above 100% are measurement noise. Samples are selection references, not production acceptance limits.

OPTICAL PERFORMANCE · CTO-016

Read the numbers.
Understand the response.

Measured wavelength range

380-800 nm. Performance outside this measured interval is not established by this curve.

400-500 nm

Approximately 25% average transmission; the range is 21.8-37.3% in the measured curve.

500-600 nm

Approximately 47.1% average transmission; the range is 26.8-73.9% in the measured curve.

600-700 nm

Approximately 88.6% average transmission; the range is 73.9-93.3% in the measured curve.

Measured edge at 60% transmission

Approximately 576.6 nm. Interpolated from the measured curve.

These values come from the measured samples and help you choose a starting design. We will agree the final specification for your order. Custom versions have their own specifications and measured curves.

OPERATING CONDITIONS

Match the complete optical system.

Match the full source band.

Compare the source emission spectrum with the filter curve. Include the source bandwidth, rather than relying on the nominal wavelength alone.

Check unwanted response.

Compare the complete measured response with your detector sensitivity. Confirm any additional blocking needed for your system.

Define the incidence conditions.

Specify the working angle and whether the beam is collimated or converging. Confirm the required response under those conditions.

Confirm the physical fit.

Provide the available mounting space, required shape, dimensions and thickness. Physical specifications will be confirmed for your assembly.

APPLICATIONS

Where this profile can help.

Architectural & Museum Lighting

Color, glare and spectral control for built environments and exhibits.

Stage, Studio & Projection

Color, patterns and beam control for performance and projection.

Imaging & Photography

Manage exposure, unwanted wavelengths and reflection.

Application examples are starting points for evaluation; suitability depends on the complete optical system.

CUSTOM & ENQUIRY

Tell us what
your design needs.

Start with CTO-016 and discuss the spectral response, physical format and operating conditions.

Include in your enquiry

  • Target wavelengths and required transmission or blocking
  • Light source and detector model, or their spectra
  • Working angle, beam geometry and operating environment
  • Required shape, dimensions, thickness and mounting constraints
  • Sample quantity, expected order quantity and project timing

TECHNICAL RESOURCES

Take the data
into your design.

CTO-016 spectrum data CSV ↓Explore Color Temperature Orange Filters →